Frequency Measurement Freq A | |
Ranges |
DC coupled: 0 to 120MHz AC coupled: 10Hz to 120MHz |
Resolution |
0.00001Hz @ 200Hz |
Gate Times |
50ms to 10s (20 settings) |
Accuracy |
?2 PPM |
Coupling |
AC or DC |
Trigger Level |
?1.8V in a scale from -99 to +99 | |
|
Frequency Measurement Freq B | |
Ranges |
DC coupled: 0 to 120MHz AC coupled: 10Hz to 120MHz |
Resolution |
0.00001Hz @ 200Hz |
Gate Times |
50ms to 10s (20 settings) |
Accuracy |
?2PPM |
Coupling |
AC or DC |
Trigger Level |
?1.8V in a scale from -99 to +99 | |
|
Frequency Measurement Freq C | |
Ranges |
100MHz to 2.4GHz |
Resolution |
100Hz @ 500MHz |
Gate Times |
50ms to 10s (20 settings) |
Accuracy |
?2PPM + 1 count |
Coupling |
AC only |
Trigger Level |
Auto | |
|
|
Input |
CH A |
Frequency Range |
DC to 10MHz |
Count Capacity |
0 to 99,999,999 counts |
Resolution |
1 count |
Accuracy |
?1 count | |
|
|
Input |
CH A and CH B |
Range |
0.5?s to 200,000?s |
Minimum Pulse Width |
250ns |
Resolution |
1?s |
Accuracy |
?1 count + timebase accuracy | |
|
|
Inputs |
CH A and CH B |
Range |
CH A: 10MHz to 150MHz CH B: 0.1MHz to 10MHz |
Resolution |
(0.000001) | |
|
|
Input |
CH A |
Measurement Range |
0.01% to 99.99% |
Frequency Range |
0 to 100KHz | |
|
|
Input |
CH A |
Measurement Range |
0 to 600,000 RPM |
Minimum Pulse Width |
250ns |
Resolution |
0.1 RPM | |
|
Input Characteristics Channel A & B | |
Frequency Range |
0 to 120MHz |
Sensitivity |
25mV |
Input Impedance |
1MW + 35?F capacitance |
Attenuator |
X1, X10 |
Maximum Input Volts |
250V DC or AC peak | |
|
Input Characteristics Channel C | |
Frequency Range |
100MHz to 2.4GHz (usable to 2.7GHz) |
Sensitivity |
25mV RMS (100MHz to 2.4GHz) |
Maximum Input voltage |
5V DC or AC peak |
Attenuator |
None |
Input Impedance |
50W | |
|
Reference Timebase Oscillator | |
Standard Frequency |
10MHz, 4.194304MHz |
Frequency Stability |
?5.0 PPM Max |
Aging Rate |
?1.0 PPM Max/Yr |
Temperature |
-30 to +60?C |
Storage Temperature Range |
-40 to +85?C | |
|
|
Software |
The supplied software is a Windows-based program, which runs under Windows 95/98/ME/XP/2000. It allows the user to set the Instrument Parameters from the PC via the RS-232 interface and provides time stamped data logging for all functions. | |
|
|
Display |
128 ? 64 pixel super twist LCD |
Line Voltage |
AC input Volts: 85 to 270VAC ?10% |
Line Frequency |
48Hz to 66Hz |
Power Consumption |
15W |
Operating Temperature |
0 to 40?C (32 to 104?F) |
Size |
3.3" H x 11.6" W ? 11.0" D |
Weight |
4.4 lbs |
Supplied Accessories |
Manual, Line cord, BNC cable, Software, RS-232 cable |
Optional Accessory |
GPIB (installed) | |