Z9216 - High Accuracy, Wide Range LCR Meter
|
" |
0.2% basic accuracy |
" |
Wide measurement range over13 orders of magnitude |
" |
Store and recall 9 instrument setups |
" |
Measurement rates to 20 times per second |
" |
Test frequencies are 100Hz, 120Hz, 1KHz, 10KHz and 100kHz |
" |
Displays component value and Q or Dissipation factor |
" |
Averaging for 2 to 10 measurements |
" |
RS-232 and optional GPIB and Handler interface |
" |
Open and short circuit compensation for accurate zeroing |
" |
Easy to use and calibrate |
" |
Built-in calibration procedures |
" |
Binning capabilities |
Specification |
|
|
Abbreviations Used |
L (inductance) C (capacitance) R (resistance) |
Measured Circuit Configurations |
series and parallel | |
|
|
Measured Parameter (R) |
R + Q |
Measurement Ranges (R) |
R: 0.0001 W to 2000 MW Q: 0.00001 to 50 |
Measured Parameter (L) |
L + Q |
Measurement Range (L) |
L: 0.0001 ?H to 99999 H Q: 0.0001 to 50 |
Measured Parameters (C) |
C + D and C + R |
Measurement Range (C) |
C: 0.0001pf to 99999?F D: 0.00001 to 10 R: 0.00001KW to 9999KW |
Display |
Values, % deviation, or bin number | |
|
|
Test Frequencies |
100Hz, 120Hz, 1KHz, 10KHz, 100KHz |
Frequency Accuracy |
? ?100 PPM |
Drive Voltages |
Fixed: 0.10, 0.25, 1.0V RMS Vernier: 0.1 to 1.0V RMS (50 mV resolution) |
Drive Voltage Accuracy |
?2% |
Measurement Rates |
[For test frequencies of 1KHz or greater] Slow: 2 measurements/Sec Medium: 10 measurements/Sec Fast: 20 measurements/Sec [For test frequencies of 100Hz and 120Hz] Slow: 0.6 measurements/Sec Medium: 2.4 measurements/Sec Fast: 6 measurements/Sec |
Bias Voltage |
Internal: +2.0 V DC ?2% External: 0 to +40 V DC |
Input Protection |
0.25A/250V Fuse |
Ranging |
Auto or manual |
Triggering |
Continuous, manual or remote (from the RS-232, GPIB or handler interface) | |
|
|
Basic Accuracy |
?0.2% with the following conditions: 1. An ambient temperature of 23?C ?5?C after a 30 minute warm up period. 2. The short and open Cal has been performed. 3. D < 0.1 for capacitance, Q < 0.1 for resistance and Q > 10 for inductance. The component value, measurement rate and frequency determine the actual measurement accuracy. (See the user manual). |
Zeroing Correction |
Open and short circuit compensation |
Remote Operation |
Interfaces: RS-232 (25 pin D female conductor), Standard GPIB and Handler (25 pin D male connector optional) | |
|
|
AC Voltage Input |
120/220V |
Frequency |
50/60Hz |
Power Consumption |
20W |
Operating Temperature |
0 to 50?C at < 80% Relative Humidity |
Size |
4.3" H ? 14.3" W ? 14.5" D |
Weight |
18 lbs |
Supplied Accessories |
Manual, Line cord, Axial lead adapter |
Optional Accessories |
GPIB and Handler interface, Kelvin clips, SMD tweezers | | |
|
|