608 - 50,000 Count, Advanced DMM with RS-232 Interface
|
" |
DC accuracy 0.05% |
" |
Low voltage Ohms measurement and conductance |
" |
Auto and software calibration |
" |
Dual back-lit display and K type thermocouple |
" |
Measures duty cycle, pulse width and conductance |
" |
Compare function for go-no go testing |
" |
Peak detection for capturing high speed signals |
" |
Binary bit expression bar graph |
" |
AC and AC + DC true RMS AC voltage and current measurements |
" |
Auto/manual ranging |
" |
Test zener diodes up to 20 volts |
" |
Min/Max/Avg relative modes |
" |
Memory store and recall |
" |
Fuse protected current ranges |
" |
Cat II 600V and CE approved |
Specification |
|
|
Ranges |
5V, 50V, 500V, 1000V |
Best Resolution |
100?V |
Accuracy |
±0.05% + 5d | |
|
|
Ranges |
500 mV to 2500mV |
Best Resolution |
10?V |
Accuracy |
±0.05% + 5d | |
|
|
Ranges |
500mV |
Best Resolution |
10?V |
Accuracy |
AC mV: ±0.75% + 20d (AC + DC) mV: ±1.5% + 50d |
AC Bandwidth |
50Hz to 20KHz | |
|
|
Ranges |
5V, 50V, 500V, 750V |
Best Resolution |
100?V |
Accuracy |
AC Volt: ±0.75% + 20d (AC + DC) Volts: ±2.0% + 50d |
Crest Factor |
Sine wave: 1.414 | |
|
|
Ranges |
5000?A, 500mA, 10 Amps |
Best Resolution |
0.1?A |
Accuracy |
±0.2% + 5d | |
|
|
Ranges |
5000?A, 500mA, 10A |
Best Resolution |
0.1?A |
Accuracy |
AC Amps: ±0.75% + 20d, 50Hz to 1KHz (AC + DC) Amps: ±1.5% + 50d, DC to 1KHz | |
|
Resistance (50 Ohm range is 5,000 count) | |
Ranges |
50W, 5KW, 50KW, 500KW, 5MW, 50MW |
Best Resolution |
10mW |
Accuracy |
±0.2% + 5d | |
|
Resistance Lo Ohms (All ranges are 5,000 count) | |
Ranges |
5KW, 50KW, 500KW; 5MW, 50MW |
Best Resolution |
1W |
Accuracy |
±0.5% + 5d | |
|
|
Range |
500nS |
Resolution |
0.1nS |
Accuracy |
±3% + 5d | |
|
Capacitance (All ranges are 5,000 count) | |
Ranges |
5nF, 50nF, 500nF, 5?F, 50?F, 500?F, 5000?F |
Best Resolution |
1pF |
Accuracy |
±2% + 5d | |
|
|
Range |
25.0V Approx. |
Accuracy |
±5% + 10d |
Test |
15V to 22V | |
|
|
Ranges |
5KW, 50KW, 500KW, 5MW |
Buzzer |
Will sound at < 0.1% of full scale of each range | |
|
|
Ranges |
-20 to 1200?C, -4 to 2100?F, 253 to 1423?K |
Display |
?C, ?F, ?K |
Resolution |
0.1? |
Accuracy |
±2?C 0 to 150?C: ±3?C | |
|
Frequency (50Hz & 500Hz ranges are 5,000 count) | |
Ranges |
50Hz, 500Hz, 50KHz, 500KHz, 5MHz |
Best Resolution |
0.01Hz |
Input Sensitivity |
2V RMS |
Accuracy |
±0.01% + 5d | |
|
|
Range |
200.01ms |
Best Resolution |
10 ?s |
Accuracy |
±0.1% + 5d | |
|
|
Range |
0 to 100% |
Resolution |
0.01% |
Accuracy |
±0.1% + 5d | |
|
|
Accuracy |
10% of peak for a duration of > 5mS | |
|
|
Operating System |
Windows 95/98/ME/XP/2000 |
Update Rates |
2/s |
RS-232 Output Medium |
Infrared |
Operating Temperature |
0 to 40?C at 80% relative humidity |
Power |
9 Volt battery @ 36 hours of continuous operation |
Size |
8.0" H ? 3.7" W ? 1.7" D (without holster) |
Weight |
15 oz |
Standard Accessories |
Manual, Protective holster, Safety probes, Temperature adapter and Probe, RS-232 cable, CD ROM | | |
|
|
To request more information, please fill the form below.
|
|
|
ITS Instruments
Under Construction..
Click here to continue.
|