Products
»
By Application
»
Oscilloscopes
»
Analog Oscilloscopes 6510
|
|
Analog Oscilloscopes 6510
|
6510 - Dual Trace, Dual Timebase, 100MHz Oscilloscope |
|
Specifications |
|
Vertical Amplifier (CH 1 and CH 2) | |
Sensitivity |
5 mV/Div to 5 V/Div in 7 calibrated steps, (X5 Mag 1mV/Div to 1 V/Div) |
Accuracy |
?3% (?5% in X5 Mag) |
Bandwidth (-3dB) |
DC to 100MHz |
Rise Time |
? 3.5ns, X5 Mag: 20MHz Bandwidth: ? 17ns |
Input Impedance |
1MW + 25pF |
Input Coupling |
AC-Gnd-DC |
Invert Channel |
CH2 |
Display Modes |
CH1, CH2, Add, Subtract, Dual (Alt/Chop) |
Maximum Input Voltage |
400V (DC or AC peak) |
CH1 Signal Output |
20mV into 50W | |
|
|
Timebase A - Sweep Time |
50ns/Div to 0.2 s/Div in 21 calibrated steps (1-2-5) |
Timebase A - X10 Mag |
5ns/Div to 20ms/Div |
Timebase A - Accuracy |
?3% (?5% in X10 Mag) |
Timebase A - Hold Off |
Continuously adjustable to > 2X sweep time |
Timebase B - Sweep Time |
50ns/Div to 10?s/Div in 8 steps (1-2-5) |
Timebase B - Accuracy |
?3% |
Timebase B - Delay Time |
Continuously variable from 0.2?s to 2s |
Timebase B - Delay Modes |
Continuous or triggered |
Timebase B - Sweep Displays |
A, B, A alt B, B triggered, X-Y | |
|
|
CH1-X axis, CH2-Y axis Sensitivity |
Same as CH1 vertical amplifier |
Bandwidth (X-axis) |
DC to 2MHz |
Phase Error |
? 3? DC to 10KHz | |
|
|
Trigger Modes |
Auto, Normal, TV-V, TV-L |
Source |
Int. CH2, line ext. |
Coupling |
AC |
Slope |
Positive or negative |
Trigger Sensitivity |
Int (DC to 10MHz): 0.5 Div Int (10MHz to 100MHz): 1.5 Div Ext (DC to 10MHz): 200mV Ext (10MHz to 100MHz): 500mV TV (Int):1 Div Min TV (Ext): 1V P-P |
External Trigger Input |
Impedance: 1MW + 20pF Maximum Input Volts: 400V DC or AC peak | |
|
|
Sensitivity |
?5V P-P Intensity increases with a negative going voltage input |
Bandwidth (-3dB) |
DC to 2MHz |
Input Impedance |
Approx. 2KW | |
|
|
Voltage |
0.5V ?3% P-P 1KHz Square Wave |
Duty Cycle |
Approx. 50% | |
|
|
Type |
6" rectangular CRT with internal graticule. (1 Div = 1cm) |
Acceleration Voltage |
12KV | |
|
|
Power Requirements |
AC Input Voltage: 100V, 120V, 220V, 240V selectable |
Frequency |
50/60Hz |
Power Consumption |
55W |
Operating Temperature |
0 to 40?C at 35% to 85% relative humidity |
Size |
5.3" H ? 12.7"W ? 14.5" D |
Weight |
24 lbs |
Supplied Accessories |
Manual, 1 AC Power cord, (2) X10 Probes | | |
|
|
To request more information, please fill the form below.
|
|
|