mV DC |
Ranges: 500 mV, 2500mV Accuracy: ±(0.05% + 5d) Best Resolution: 10?V |
DC Volts |
Ranges: 5V, 50 V, 500V, 1000V Accuracy: ±(0.05% + 5d) Best Resolution: 100?V |
AC and AC + DC mV |
Ranges: 500mV AC mV Accuracy: ±(0.75% + 20d) AC+ DC mV Accuracy: ±(2.0% + 50d) Best Resolution: 10?V |
AC and AC + DC Volts |
Ranges: 5.V to 750V AC Volts Accuracy: ±(0.75% + 20d) AC + DC Volts accuracy: ±(2.0% + 50d) Crest factor: Sine wave: 1.414 |
DC Current |
Ranges: 5000?A, 500mA, 10A Accuracy: ±(0.2% + 5d) |
AC and AC+DC True RMS Current |
Ranges: 5000?A, 500mA and 10A AC Amp Accuracy: ±(0.75% + 2d) 50Hz to 1KHz AC + DC Amp Accuracy: ±(1.5% + 50d) DC to 1KHz |
Resistance |
Ranges: 50W to 50MW (50W range is 5,000 count) Accuracy: ±(0.2% + 5d) Best Resolution: 10mW Open Circuit Voltage: 2.5V |
Resistance: Lo Volt Ohms (5,000 count) |
Ranges: 5KW to 50MW Accuracy: ±(0.5% + 5d) Best Resolution: 1W Open Circuit Voltage: 0.25V |
Conductance |
Range: 500ns Accuracy: ±(3% + 5d) Best Resolution: 0.1ns |
Capacitance (5,000 count) |
Ranges: 5nF, to 5000?F Accuracy: ±(3% + 5d) Best Resolution: 1pF |
Zener Diode Test |
Range: 15.00V Test Current: 1mA Test Voltage: 15 to 22V Accuracy: ±(5% + 10d) |
Continuity Test |
Ranges: 5KW to 5MW Buzzer will sound <0.1% of full scale of each range |
Temperature |
Ranges: -20?C to 1200?C, -4?F to 2100?F, -253?K to 1473?K Thermocouple: K type Display: ?F, ?C, and ?K Accuracy: ±(2?C +10d) |
Frequency (50Hz and 500Hz are 5,000 count) |
Ranges: 50Hz to 5MHz Accuracy: ±(0.01% + 5d) Best Resolution: 0.01Hz Sensitivity: 2Vrms or 4V p-p Max |
Pulse Width |
Range: 200ms Accuracy: ±(0.1% + 5d) Best Resolution: 10?s |
Duty Cycle |
Range: 0 to 100% Accuracy: ±(0.1% + 5d) Best Resolution: 0.01% |
Peak Hold |
Functions: DCV, DC ?A, DC mA, DCA Accuracy: < 10% of peak with > 5ms pulse width and > 10% of full scale |