Measurement range |
500 ... 1100 hPa, 50 ... 1100 hPa |
|
Accuracy at +20 °C |
|
|
Class A 500 ... 1100 hPa |
±0.10 hPa |
|
Class B 500 ... 1100 hPa |
±0.20 hPa |
|
50 ... 1100 hPa |
±0.30 hPa |
|
Total accuracy (-40...+60 °C/-40...+140 °F) |
|
|
Class A 500 ... 1100 hPa |
± 0.15 hPa |
|
Class B 500 ... 1100 hPa |
± 0.25 hPa |
|
50 ... 1100 hPa |
± 0.45 hPa |
|
Long-term stability |
|
|
Class A 500 ... 1100 hPa |
± 0.1 hPa |
|
Class B 500 ... 1100 hPa |
± 0.1 hPa |
|
50 ... 1100 hPa |
± 0.2 hPa |
|
Sensor |
Vaisala BAROCAP® |
Relative humidity measurement
|
|
Measurement range |
0 ... 100 %RH |
|
Accuracy (including non-linearity and hysteresis) at +15 … +25 °C |
± 1 %RH (0 … 90%)± 1.7 %RH (90 … 100%) |
|
Sensor |
Vaisala HUMICAP®180Vaisala HUMICAP® 180R |
Temperature measurement
|
|
Measurement range |
-40 ... +60 °C (-40 ... +140 °F) |
|
Accuracy |
|
|
at -40 °C (-40 °F) |
± 0.4 °C (±0.8 °F) |
|
at +20 °C (68 °F) |
± 0.2 °C (±0.4 °F) |
|
at +60 °C (140 °F) |
± 0.3 °C (±0.6 °F) |
|
Sensor |
Pt100 RTD 1/3 Class B IEC 751 |
Operating environment
|
|
Temperature range with displayHumidity range
|
-40 ... +60 °C (-40 … +140 °F)0 ... +60 °C (+32 … +140 °F)non-condensing
|
Inputs and outputs
|
|
Operating voltage |
|
|
with an optional power |
10 ... 35 VDC |
|
supply module |
100 … 240 VAC |
|
Analog outputs (optional) |
|
|
current outputs |
0 … 20 mA, 4 … 20 mA |
|
voltage output |
0 … 1 V, 0 … 5 V, 0 … 10 V |
|
Serial interface |
RS-232C, RS-485 |
|
Ethernet interface (optional) Supported standards |
10/100Base-T |
|
Connector |
RJ45 |
|
Protocols |
Telnet |
|
WLAN interface (optional) |
|
|
Supported standards |
802.11b |
|
Antenna connector type |
RP-SMA |
|
Protocols |
Telnet |
|
Security |
WEP 64/128,WPA |
|
Authentication / Encryption |
|
|
Open / no encryption |
|
|
Open / WEP |
|
|
WPA Pre shared key / TKIP |
|
|
WPA Pre shared key / CCMP (a.k.a. WPA2) |
|
|
Optional data logger with real-time clock |
max. three with trend/min/max values |
|
Logged parameters |
10 sec (fixed) |
|
Logging interval |
4 years 5 months |
|
Max. logging period |
13,7 million points per |
|
Logged points |
parameter |
|
Battery lifetime |
min. 5 years |
|
Display |
LCD with graphic trend display |
Calculated quantities
|
|
Humidity parameters |
Dewpoint temperature (Tdp)Absolute humidity (a)Mixing ratio (x)Wet bulb temperature (Tw)Water vapour pressure (Pw)Entalphy (h) |
|
Pressure parameters |
QNH PressureQFE PressureHeight corrected pressure HCPWMO Pressure tendency code |