Relative humidity measurement
|
|
Measurement range |
0 ... 100 %RH |
|
Accuracy |
|
|
at +15 ... +25 °C |
±1.7 %RH (0 ... 90 %RH) |
|
|
±2.5 %RH (90 ... 100 %RH) |
|
Sensor |
Vaisala HUMICAP® 180 |
Temperature measurement
|
|
Measurement range |
-40 ... +80 °C (-40 ... 176 °F) |
|
Accuracy at +20 °C
(+68 °F) |
± 0.2 °C (± 0.36 °F) |
|
Sensor |
Pt1000 IEC 751 1/3 class B |
Dewpoint measurement (calculated)
|
|
Measurement range
|
-20 ... +80 °C (+4 ... +176 °F)
|
Operating environment
|
|
Temperature
w/o display
probe only
|
-30 ... +60 °C (-22 ... +140 °F)
-40 ... +60 °C (-40 ... +140 °F)
-40 ... +80 °C (-40 ... +176 °F)
|
Inputs and outputs
|
|
Two-wire output signal |
4 ... 20 mA |
|
external loop load |
10 ... 35 VDC (RL = 0 ohms)
20 ... 35 VDC (RL = 500 ohms) |
|
Voltage output signals |
|
|
supply voltage |
0 ... 1 V, 0 ... 5 V, 0 ... 10 V |
|
current |
10 ... 35 VDC/24 VAC |
|
consumption, |
|
|
35 VDC/24 VAC |
max. 12 mA |
|
external load |
RL min. 10 k& |
Mechanics
|
|
Probe cable length
Materials
Housing
Probe
Mounting plate
Housing classification
Display option
|
3 m, 5 m, 10 m
ABS/PC plastic
Chrome coated aluminum
ABS plastic
IP65 (NEMA 4)
One line, changing variable or xed variables when two variables are ordered.
|
Options and accessories
|
|
Radiation shield |
DTR502B |
|
Rain shield with installation kit |
215109 |
|
Installation plate |
DRW010712 |
|
Duct installation kit |
215619 |
|
Connection cable for HM70 |
211339 |