The Vaisala HydroMet™ System MAWS100 extends the field-proven quality and reliability of the existing Vaisala HydroMet™ Systems to new applications. The MAWS100 is a compact system for hydrometeorological monitoring when a small number of sensors is required. The MAWS100 is well suited for Vaisala Weather Transmitter WXT510 and cellular telemetry.
MAWS100 uses the same field-proven and high accuracy data logger and advanced software as other Vaisala HydroMet™ Systems. Data retrieval can be done by direct link to PC via serial or TCP/IP connection, via PSTN modem or using wireless cellular telemetry links. Flexible sensor interfacing, advanced statistical calculations, extensive data logging on a compact flash memory card and versatile data reporting functions allow the MAWS100 to be customized for a variety of applications.
General
|
|
|
Data Collection Platform with Vaisala Setup Software Lizard |
Vaisala Data Logger QML201
|
Temperature |
Operating *) |
-50 ... +60 °C (-58 ... 140 °F) |
Storage |
-50... +70 °C (-58 ... 158 °F) |
Humidity |
0 ... 100 % RH |
EMC |
|
In compliance with EN 61326-1 (2001-12)
Electrical equipment for measurement, control and laboratory
use - EMC requirements - for use in industrial locations
|
|
IP rating |
NEMA-4X / IP-66 |
Materials |
Stainless steel |
|
Plastic |
Mast**) |
Tiltable 2/3/4/6/10 m (6/9/12/24/30 ft) pole mast |
Enclosure |
400(H) x 100 (W) x 200 (D) mm |
Weight |
Enclosure approx 10 kg |
|
Mast with sensors approx 20... 200 kg |
Maximum wind speed |
With one set of guy wires 50 m/s (90 kt) |
|
With two sets of guy wires 75 m/s (130 kt) |
Powering **) |
90 ... 264 VAC, 45 ... 65 Hz |
|
8 ...14 VDC recommended (30 VDC max.) |
Solar panel |
11 W |
Internal battery |
5 Ah / 12 V |
Battery regulator |
Charge/recharge control |
|
Temperature compensation |
|
Deep discharge protection |
|
Simultaneous inputs from solar and AC power allowed |
Data validation, calculations and reports
|
|
|
Data quality control |
Upper / lower climatological limits |
|
Step change validation |
|
Sensor status indication |
Statistical calculations |
Averaging over user set periods |
|
Minimum / maximum values |
|
Standard deviation |
|
Cumulative values |
Other calculations |
Dew point |
|
Frost point |
|
QNH, QFE, QFF |
|
Gust, Squall, wind chill |
|
Evapotranspiration |
|
Sunshine duration |
Standard sensor options **)
|
|
|
Weather transmitter |
WXT520
|
|
|
Wind speed & direction |
WM30, WA15, WA25, WINDSONIC,
WMT52, WS425
|
|
|
Atmospheric pressure |
PMT16A
|
|
|
|
PTB330 with modifications
|
|
|
Air temperature, relative humidity & dew point |
QMH102
|
|
|
Rain / precipitation |
QMR102, RG13, RG360, VRG101
|
|
|
Global solar radiation |
QMS101, SK01-D2, SK08, CMP3, CMP6
|
|
|
|
CMP11, CMP21, EQ08, EQ08-S
|
|
|
Net solar radiation |
QMN101
|
|
|
Albedometers |
QMS101(x2), CMP3(x2), CMA6, CMA11, EQ16
|
|
|
UV radiation / PAR |
CUV4, UVR1-A, UVR1-B, PAR Lite
|
|
|
Sun duration |
CSD3, SD4
|
|
|
Ground / water temperature |
|
|
|
Soil / fuel moisture |
EHC20, ML2X, QFM101 |
|
|
Evaporation |
255 Series |
|
|
Leaf wetness |
QLW102 |
|
|
Cloud height & sky condition |
CL31
|
|
|
Visibility & present weather |
PWD10/20/12/22, FD12, FD12P, FS11
|
|
|
Snow depth |
IRU-9429S |
|
|
Water level |
PR-36XW/H, PAA-36XW/H, IRU-9429S,
QHR102, QSE104, 436BD
|
|
|
Standard communication options **)
|
Wireless communication |
GSM, GPRS |
Landline communication |
RS232, RS485 bus, Fixed line,
PSTN, LAN, MODBUS |
Data display options**)
|
|
|
Data displays |
DD50, WD30(TU), WD50, Pocket / Laptop /
Tabletop PC |
|