General
|
Data Collection Platform |
Vaisala Data Logger QML201A |
Temperature |
|
Operating *)
|
-50 ... +60 °C (-58 ... 140 °F) |
Storage
|
-50 ... +70 °C (-58 ... 158 °F) |
Humidity |
0 ... 100 % RH |
|
|
In compliance with Lloyd’s Register (LR) Type Approval System, Test Specification Number 1; 2002, Performance and Environmental Test Specification for the Environmentally Tested Products used in Marine and Offshore Applications, and IEC 60945 International Standard, 4th edition, 2002-08, Maritime Navigation and Radiocommunication Equipment and Systems - General Requirements Methods of Testing and Required Test Results, as follows: |
|
|
Vibration |
IEC 60068-2-6/IEC 60945 |
Shock |
MIL-STD-202G, Method 213B, cond. J |
Earthquake |
NEBS/Bellcore GR-63-CORE, risk-zone 4 |
Dry heat |
IEC 60068-2-2/IEC 60068-2-48 |
Damp heat |
IEC 60068-2-30, Test Db |
Extreme conditions |
IEC 60068-2-3, Test Ca |
Low temperature |
IEC 60068-2-1 Test Ab/Ad |
Rain & spray |
IEC 60529/IEC 60945 |
Corrosion & salt mist |
IEC 60068-2-52, Test Kb |
Conducted LF immunity |
IEC 61000-4-16 |
Conducted RF immunity |
IEC 61000-4-6 |
EFT immunity |
IEC 61000-4-4 |
Surge immunity |
IEC 61000-4-5 |
ESD immunity |
IEC 61000-4-2 |
Dielectric tests |
IEC 60947-2 |
Conducted emissions |
CISPR 22 **) |
Radiated emissions |
CISPR 22 **) |
RF field immunity |
IEC 61000-4-3 |
Insulation resistance |
IEC 60092-504 |
Power supply short term variation immunity |
IEC 61000-4-11 |
Power supply failure immunity |
IEC 61000-4-11/IEC 60092-504 |
Compass safe distance |
ISO 694 and IEC 61000-4-8 |
|
|
Materials |
Acid-proof stainless steel |
|
Anodized sea aluminium |
|
Plastic |
Mast ***) |
Tiltable 2/3/4 m pole mast |
Enclosure |
400 (H) x 300 (W) x 200 (D) mm |
Weight |
Enclosure approx 10 kg |
|
Mast with sensors approx. 20 ... 30 kg |
Powering ***) |
90 ... 264 VAC, 45 ... 65 Hz |
|
8 ... 14 VDC recommended (30 VDC max.) |
Internal battery |
7 Ah/12 V |
Battery regulator |
Charge/recharge control |
|
Temperature compensation |
|
Deep discharge protection |
|
Simultaneous inputs from solar and AC power allowed |
Data validation, calculations and reports
|
Data quality control |
|
Upper/lower climatological limits |
Step change validation |
|
Sensor status indication |
|
Cross-check |
Statistical calculations |
Averaging over user set periods |
|
Minimum/maximum values |
|
Standard deviation |
|
Cumulative values |
Other calculations |
Dew point |
|
QNH, QFE, QFF, pressure tendency |
|
True & relative wind, wind selection (upwind) |
|
Corrections for elevation & magnetic variation |
Message inputs/outputs |
|
|
NMEA 0183 MVW/XDR message output |
|
NMEA 0183 HDT/RMC/VTG/GLL message input |
Weather data reports (w/ Vaisala Observation Console sw) |
|
|
WMO FM 13 |
|
WMO IMMT-3 |
|
Custom reports |
Standard sensor options ***)
|
Wind speed & direction |
WINDSONIC, WMT50, WS425 |
Atmospheric pressure |
PMT16A |
Air temperature, relative humidity & dew point |
QMH102, HMT330 |
Rain/precipitation |
Model 50202, DRD11A |
Water temperature |
DTS12W |
Solar radiation/sun duration |
CMP3, CMP6, CMP11, CUV4, SD4 |
Digital compass |
QCO201 |
Position and time |
Position and time |
Standard communication options ***)
|
Satellite communication |
Iridium, Inmarsat-C, Argos/SCD |
Wireless communication |
UHF, VHF, GSM, GPRS |
Landline communication |
RS232, RS485 bus, PSTN, Fixed line, LAN, Optical fibre |
Data displays |
DD50, WD30(TU), WD50, Pocket/Laptop/Tabletop PC |
|
|
*) for further extended range, please contact Vaisala |
**) limits according to IEC 60945 |