Vaisala Maritime Observation System MAWS410

In continuation of the successful adaptation of automatic data collection and processing systems for maritime applications, Vaisala has developed the new generation Vaisala Maritime Observation System MAWS410 covering the most demanding maritime weather observation requirements of moving platforms and fixed offshore installations.

The Vaisala Maritime Observation System provides you with continuous 24-hour automatic shipboard weather observations. Direct satellite communication links can be used to send coded meteorological data sets to the global network, in real-time.

Intended to be set up on Voluntary Observing Ships (VOS) the system measures, observes and calculates all the basic surface weather parameters including wind speed and direction, atmospheric pressure, air temperature and humidity, and elements related to the position, course and speed of the ship. For the most accurate true wind calculation the vessel's own gyro compass and navigation system are used providing the required heading and ship's speed, direction and location information.

The MAWS410 system has passed a demanding environmental and EMC test program, which guarantees that the system exceeds the requirements of IEC-60945 and Lloyd's Register's type approval system, both internationally respected marine standards.

General

Data Collection Platform Vaisala Data Logger QML201A
Temperature
Operating *)
-50 ... +60 °C (-58 ... 140 °F)
Storage
-50 ... +70 °C (-58 ... 158 °F)
Humidity 0 ... 100 % RH
In compliance with Lloyd’s Register (LR) Type Approval System, Test Specification Number 1; 2002, Performance and Environmental Test Specification for the Environmentally Tested Products used in Marine and Offshore Applications, and IEC 60945 International Standard, 4th edition, 2002-08, Maritime Navigation and Radiocommunication Equipment and Systems - General Requirements Methods of Testing and Required Test Results, as follows:
Vibration IEC 60068-2-6/IEC 60945
Shock MIL-STD-202G, Method 213B, cond. J
Earthquake NEBS/Bellcore GR-63-CORE, risk-zone 4
Dry heat IEC 60068-2-2/IEC 60068-2-48
Damp heat IEC 60068-2-30, Test Db
Extreme conditions IEC 60068-2-3, Test Ca
Low temperature IEC 60068-2-1 Test Ab/Ad
Rain & spray IEC 60529/IEC 60945
Corrosion & salt mist IEC 60068-2-52, Test Kb
Conducted LF immunity IEC 61000-4-16
Conducted RF immunity IEC 61000-4-6
EFT immunity IEC 61000-4-4
Surge immunity IEC 61000-4-5
ESD immunity IEC 61000-4-2
Dielectric tests IEC 60947-2
Conducted emissions CISPR 22 **)
Radiated emissions CISPR 22 **)
RF field immunity IEC 61000-4-3
Insulation resistance IEC 60092-504
Power supply short term variation immunity IEC 61000-4-11
Power supply failure immunity IEC 61000-4-11/IEC 60092-504
Compass safe distance ISO 694 and IEC 61000-4-8
Materials Acid-proof stainless steel
Anodized sea aluminium
Plastic
Mast ***) Tiltable 2/3/4 m pole mast
Enclosure 400 (H) x 300 (W) x 200 (D) mm
Weight Enclosure approx 10 kg
Mast with sensors approx. 20 ... 30 kg
Powering ***) 90 ... 264 VAC, 45 ... 65 Hz
8 ... 14 VDC recommended (30 VDC max.)
Internal battery 7 Ah/12 V
Battery regulator Charge/recharge control
Temperature compensation
Deep discharge protection
Simultaneous inputs from solar and AC power allowed

Data validation, calculations and reports

Data quality control
Upper/lower climatological limits Step change validation
Sensor status indication
Cross-check
Statistical calculations Averaging over user set periods
Minimum/maximum values
Standard deviation
Cumulative values
Other calculations Dew point
QNH, QFE, QFF, pressure tendency
True & relative wind, wind selection (upwind)
Corrections for elevation & magnetic variation
Message inputs/outputs
NMEA 0183 MVW/XDR message output
NMEA 0183 HDT/RMC/VTG/GLL message input
Weather data reports (w/ Vaisala Observation Console sw)
WMO FM 13
WMO IMMT-3
Custom reports

Standard sensor options ***)

Wind speed & direction WINDSONIC, WMT50, WS425
Atmospheric pressure PMT16A
Air temperature, relative humidity & dew point QMH102, HMT330
Rain/precipitation Model 50202, DRD11A
Water temperature DTS12W
Solar radiation/sun duration CMP3, CMP6, CMP11, CUV4, SD4
Digital compass QCO201
Position and time Position and time

Standard communication options ***)

Satellite communication Iridium, Inmarsat-C, Argos/SCD
Wireless communication UHF, VHF, GSM, GPRS
Landline communication RS232, RS485 bus, PSTN, Fixed line, LAN, Optical fibre
Data displays DD50, WD30(TU), WD50, Pocket/Laptop/Tabletop PC
*) for further extended range, please contact Vaisala
**) limits according to IEC 60945
***) for other mast, solar powering, sensor and communication options, please contact Vaisala


To request more information, please fill the form below.