SPECIFICATIONS:

- Power Supply: 200 - 260VAC @ 5.5VA
- Inputs: The inputs may be activated by a potential free contact or open collector NPN transistor output.
- RS485: 2 Wire Multidrop twisted. (9600 BAUD only)
- Indicators: LED indicators show RX and TX communications.
- Connectors: 2 X 10 way plug in screw connectors.

 

DESCRIPTION



MOD-MUX is an innovative modular I/O system which provides a simple low cost solution for distributed I/O requirements. The MOD-MUX system consists of stand-alone Digital and Analog Input and Output modules which are connected together on a RS485 two wire multi-drop network using the MODBUS protocol. Two baud rates are selectable, 9600 and 19200 baud. Typical response times are under 50ms.

All MOD-MUX modules plug into industry standard DIN rail mount 11 pin relay bases. All modules have a minimum isolation of 1000VAC rms between the field and logic.

There are a number of configurations in which the MOD-MUX modules may be used in a system. Some are listed as follows:

A. Simple Point to Point I/O.

This is the basic configuration were a maximum of 8 Digital or Analog Inputs will be transmitted to 8 Digital or Analog Outputs at a remote location on the network. The primary advantage of this configuration is cost saving where 9 wires are replaced by a single twisted pair. It may also be used on existing installations to avoid having to install additional cabling for expansion purposes.
B. Complex Point to Point I/O.

This configuration allows for a larger number of I/O to be connected to the network at random
points on the network. A maximum of 32 Digital Input Modules and 16 Analog Modules may
be placed on the network, and the inputs are transmitted to a corresponding number of
Digital or Analog Output Modules. In this configuration the Modules are set to operate in
the MODBUS Slave mode and a Master Module called an I/O MAPPER is used to transmit
the Inputs from the Input Modules to the Outputs on the Output Modules.
 

C. I/O Expansion.
There are a number of devices such as PLC s (Programmable Logic Controllers) which have
a MODBUS Communications facility available. When configured as a MODBUS Master, and
attached to the RS485 network, MOD-MUX Modules may be used as remote I/O reducing
cabling costs and increasing the I/O capability of the PLC.
 

D. Data Acquisition.

Another use of the MOD-MUX Modules is for Data Acquisition where a PC (Personal
Computer) is connected to the Network. Many SCADA software packages support the
MODBUS Master Protocol and can hence retrieve data from Input Modules or send data to
Output Modules. The serial port of the PC is connected to an RS232/RS485 Converter
which in turn is connected to the Network.
 


MODULE SELECTION TABLE

MODEL

MODULE TYPE

 

POWER SUPPLIES

MMPSU150 220VAC / 2 x 12Vdc UNREG.POWER SUPPLY 150mA
MMPSU151 220VAC / 24Vdc UNREG.POWER SUPPLY 150mA

 

I/O MODULES

MM8DI 8 DIGITAL INPUT MODULE INCLUDING 8 COUNTERS
MM8DIB 8 DIGITAL INPUT MODULE WITH BATTERY BACKED COUNTERS
MM16DI 16 DIGITAL INPUT MODULE INCLUDING 8 COUNTERS
MM8DO 8 DIGITAL OUTPUT MODULE
MM4DIO 4 DIGITAL INPUT / 4 DIGITAL OUTPUT MODULE
MM4RO 4 RELAY OUTPUT MODULE
MM8AI/V 8 ANALOG INPUT 0 - 5V / 1 - 5V / 0 - 10V / 2 - 10V
MM8AI/V ISO 8 ANALOG INPUT 0 - 5V / 1 - 5V / 0 - 10V / 2 - 10V FULLY ISOLATED
MM8AI/I 8 ANALOG INPUT 0 - 20mA / 4 - 20mA
MM8AI/I ISO 8 ANALOG INPUT 0 - 20mA / 4 - 20mA  FULLY ISOLATED
MM8AO 8 ANALOG OUTPUT MODULE
MM8TC 8 THERMOCOUPLE INPUT MODULE INCL. 0 - 50mV I/P
MM8TCISO 8 TC INPUT MODULE INCL. 0 - 50mV I/P FULLY ISOLATED
MM6RTD 6 RTD INPUT MODULE - PT100 & Ni120
MM6RTDB 6 RTD INPUT MODULE - PT1000
MM1AI2RO 1 ANALOG INPUT 0(4) - 20mA / 0(2) - 10V / 0(1) - 5V WITH DUAL ALARMS
MM1TI2RO 1 TEMPERATURE INPUT   TC / RTD  WITH DUAL ALARMS
MMMEM MEMORY MODULE

 

COMMUNICATION MODULES

MMTCPCONV MODBUS/TCP RS485 CONVERTER
MMINTCONV RS232 / RS485 INTELLIGENT CONVERTER
MMINTBCONV RS232 / RS485 INTELLIGENT BOXED CONVERTER
MMDUALCONV DUAL MASTER RS232 / RS485 BOXED CONVERTER
MM485REP RS485 REPEATER
MM232OPTO RS232 / FIBRE OPTIC CONVERTER 850nm
MM485OPTO RS485 / FIBRE OPTIC CONVERTER 850nm

 

MODBUS MASTERS

MMI/OMAP I/O MAPPER

 

ACCESSORIES

MM11PINBASE 11 PIN DIN RAIL MOUNT BASE
MM232CBL RS232 9-PIN D-TYPE CONNECTOR AND CABLE

 

DISPLAYS

UCLK UNIVERSAL CLOCK
UCNTR6A UNIVERSAL 6 DIGIT COUNTER
UDISP6A UNIVERSAL 6 DIGIT DISPLAY
UCLK6LA UNIVERSAL CLOCK  100mm DISPLAY
UCNTR6LA UNIVERSAL 6 DIGIT COUNTER  100mm DISPLAY
UDISP6LA UNIVERSAL 6 DIGIT DISPLAY  100mm DISPLAY

 

MISCELLANEOUS

MM-LPI LOOP POWERED ISOLATOR 4 - 20mA
MM232/485CONV RS232/RS485(422) ISOLATED CONVERTER
DU01 DIAGNOSTIC UNIT
   

MODBUS TCP MODULES

MMTCP16DI 16 DIGITAL INPUT MODULE WITH 8 COUNTERS
MMTCP16DO 16 DIGITAL OUTPUT MODULE
MMTCP8AI/V 8 ANALOG INPUT 0-5V / 1-5V / 0-10V / 2-10V
MMTCP8AI/I 8 ANALOG INPUT 0-20mA / 4-20mA
MMTCP8AO 8 ANALOG OUTPUT 0-20mA
MMTCP8TC 8 THERMOCOUPLE INPUT MODULE
MMTCP6RTD 6 RTD INPUT MODULE PT100, Ni120
MMTCPCONV MODBUS TCP / RS485 CONVERTER

 