Home | About Us | Products | Services | Careers | Contact Us | Resources | Testimonials
 
2300 Series Controller
2200 Series Controllers
Shark Controllers & Analyzers
pH & ORP Sensors
SHARK Txp Transmitters
SHARK Tx Transmitters
Free Residual Chlorine Analyzer
AM-FCL Free Chlorine Direct Output Sensor
Electrodeless Conductivity Sensors
Dissolved Oxygen System
MS Series Conductivity & Resistivity Sensors
AS Series Conductivity Sensors
AM Series Conductivity Sensor
AM-LDO Luminesescent Dissolved Oxygen
AM-TBR Turbidimeters
Portable Level & Velocity Logger
Doppler Flow Meter
Area Velocity Flow & Level Monitor
Flow Sensors
Power Generation Systems
Ultrasonic Flow & Level Monitor
AM-HLT Hydrostatic Level Transducers
AM-UST-mini Ultrasonic Transducer
LL Series Liquid Level Controllers
EX80 Fixed Insertion Magmeter
EX100 Variable Insertion Magmeter
 
ITS Instruments   Under Construction..

  Click here to continue.
2200P pH Controller/Analyzer

Features

• Simple step-through menu design for quick & easy setup
• Bidirectional control through two control relays with independent setpoints for Relay On and Relay Off
• Cycle-Time option minimizes chemical overshoot
• High/low alarm relay
• ALARM LED on front panel
• Accepts P60 Series
• differential pH probes with replaceable salt bridge orstandard combination pHprobes
• Output signal is field-scalable for maximum resolution
• Automatic buffer recognition
• STATUS errors illuminate LED on front panel
• Test feature allows simulation of pH readings to test relay
• Setpoints and analog settings Password protection and 
watchdog timer provide security

Technical Data
Display Measuring Range
4 x 7 segment 1/2” LED Display
Indicator Lights: 4 LED indicators: Status, Alarm, Relay A, Relay B
pH:                    0.00 to 14.00 pH
Temperature:    0 to 100°C (32 to 212°F)
Power Requirements Calibration
Standard:                    98-132 Vac 50/60 Hz, (less than 10 VA)
Optional:                     196-264 Vac 50/60 Hz (less than 10 VA)
                                   23-26 Vdc (nominal current: 150 mA
)
2 point, manual or automatic buffer recognition
Ambient Conditions Temperature Compensation
Temperature:            -30 to 50°C (-22 to 122°F)
Humidity:                   0 to 90% RH non-condensing
Automatic:    0-100°C (32 to 212°F) if probe has temperature sensor
Sensitivity Stability
0.1% of span 0.1% of span per 24 hours non-cumulative
Control Relays Test
Number:                   Two Control Relays: Relay A, Relay B
Rating:                      5A 115/230Vac, 5A 30Vdc SPDT
Bidirectional:            Relays factory preset for bidirectional
                                 control can be individually field set
                                 for rising or falling pH.
On / Off Setpoints:    Field selectable 0.00 - 14.0 pH.
Cycle Timer:             Field selectable on and off times 0-600sec
Manual Override:      Relay A only: AUTO/OFF/ON
Fail- safe:                 Normal or fail safe operation
Display value and analog outputs can be set to any value for testing and diagnostic purposes.
Alarm Relays Analog Ouput
Number:                   One Alarm Relay
Rating:                     5A 115/230Vac, 5A 30Vdc, SPDT
Alarm High:              Field selectable 0 -14pH
Alarm Low:               Field selectable 0 -14pH
Deadband:                Fixed at 2% of full scale
Fail-safe:                  Normal or fail safe operation
Relay Indicators:      Three individual LEDs indicate

Non-isolated:       0-1 mA, 100 ohms maximum load
Non-isolated:       0-5 Vdc, 1000 ohms minimum load
Isolated:              4-20 mA, 800 ohms maximum load
Output:                is isolated from the input, the ground,
                           line power and all other outputs.
Range Expand:    Analog outputs can be scaled to represent 
                           any segment of the instrument scale, minimum 
                           of 10% of full scale.                       
Output Hold:        Analog outputs are placed on hold when the 
                           instrument is in menu mode.
Temperature:      The 0-1mA and 0-5Vdc outputs can be selected 
                           to track either the pH or the temperature of 
                           the process