Programmable Controller LC700

LC700
Programmable Controller

The LC700 is a powerful Universal Hybrid Controller that can be used as a stand-alone or a full participant of Smar System302. Smar's excellence in design was consistently applied to the LC700 to make it more reliable and dependable even in the most demanding industrial environments and applications.

Experience
The LC700 is the seventh generation of controllers from Smar, and our experience from a wide range of industries is reflected
in this device. Since its introduction it has been successfully field proven in many simple and complex installations in a
wide range of industries, e.g., petrochemical, water treatment, pharmaceutical, food industry, sugar mill, power plants,
pollution control among others.

Universal Hybrid Controller
As a Universal Hybrid Controller, the LC700 was designed from the beginning with traditional discrete manufacturing automation tasks, continuous regulatory process control, and batch control in mind.

As a hybrid controller, it has the logic capability and speed of a traditional programmable logical controller, and the regulator features and power of a DCS. A powerful hardware platform with a wide range of conventional I/O modules and field communications modules for leading industrial networks combined with an extensive set of programming function blocks and logic elements makes the LC700 extremely versatile.

Smar can be a one-stop solution for many different applications. Today, Smar offers a complete line of Controllers, Software, Field Devices and Industrial Networking all integrated for your convenience. Moreover, your purchasing and vendor relations become simplified.

The CONF700 is a Windows based configurator for the LC700.

Get the CONF700 FREE

  • True Industrial Universal Hybrid Controller.
  • Slim hardware and code for reliability and dependability.
  • Fault tolerant for high availability with many levels of redundancy.
  • Compact, modular and scaleable.
  • Remote I/O for distributed and long distance data transfer.
  • Ready for Foundation Fieldbus, Profibus, DeviceNet and Modbus.
  • Modbus/TCP and Modbus RTU for control network.
  • Ethernet and/or Serial OPC server for HMI clients.

General Specifications:

Power Voltage
90-264 Vac (45-65Hz) / 20-40 Vdc
Consumption
35 VA
Operating Temperature
0 ?C to 60 ?C (32 ?F to 140 ?F) or 0 ?C to 50 ?C (32 ?F to 122 ?F) see specifications module
Cooling Method
Air Convention
Storage Temperature
-20 ?C to 80?C (-4 ?F to 176 ?F)
Ambient Humidity
20 to 90% (no condensing)
Vibration Humidity
5 Hz a 2 Khz, 0.4 mm pp/2.5 g de panel mounted, 1 hr per axis
Shock Humidity
10 g, 2 Times
Noise Immunity
1.000 Vpp, 1 ?s
Ambient Atmosphere
No corrosive gases or dust accumulation

 

Functional Specifications:

Universal True Hybrid Controller
  • Discrete and Analog operation
  • 1024 Discrete Points*
  • 1024 Analog points*
  • Complete set of logical elements
  • Process control Function Blocks; PID, PID Step, A/M,...
  • Setpoint generator, linearization, crossed limits...
Redundancy
Hot standby redundancy for power supply, controller, rack, control network, Remote I/O and OPC Server
IEC-61131-3
Ladder Logic with Function Blocks and Boolean equation (for click to write)
Control network
Ethernet (Modbus TCP) or Serial Modbus RTU
Field Network
  • Remote I/O
  • Foundation Fieldbus
  • Profibus-DP and Profibus-PA
  • DeviceNet
  • Modbus RTU
Programming Cycle and I/O Scan
Float scan from 5 ms (depending on the program size)
Modularity
Up to 15 local racks and up to 6 sub-systems (remote I/O)
Remote I/O
Up to 6 Rio sub-systems (maximum of 15 racks per system)
OPC Server
Multichannel OPC Server (Serial and Ethernet Combination)
Documentation
Many selectable configurations (CONF700)

 

CPU Modules Processor:

Model
CPU-700-D3
Number of Ports
3 Independent Ports
P1 - Modbus RTU (RS-232C)
P2 - Modbus RTU (RS-485)
P3 - Modbus RTU or E/S Remota (RS-485)
Connection of Ports
P1 - DB9 Female
P2 and P3 Terminals
Remote I/O Type
Master
Baud Rates:
P1 - 1200bps to 57.6Kbps
P2 - 1200bps to 115.2Kbps
P3 - as Modbus RTU 1200bps to 115.2Kbps
P3 - (as Remota I/O) 57.6Kbps to 230.4Kbps
EIA-485 Isolation
1600Vrms @ 1 minute
2000Vrms @ 1 second
Configuration Memory
NVRAM
Remote I/O Works with
RIO-700-D3
Operation LEDs and Diagnostic
Power Supply
Functioning
Hold
Safe
Communication
Fail
Internal Power Supply Current Consumption 5Vdc
240 mA

* Remote I/O Port Works in Conjunction with RIO-700-D3.

 

Remote I/O Interface:

Model
RIO-700-D3
Modbus RTU Port
EIA-232 (DB9 Female)
Redundant Remote I/O Ports
Two EIA-485 (Terminals)
Remote I/O Port
Type
Slave
Baud Rates:
Modbus RTU Port 1200bps to 57.6Kbps
Remote I/O Ports 57.6Kbps to 230.4Kbps
Isolation
on RS-485
1600Vrms @ 1 minute
2000Vrms @ 1 second
Configuration Memory
NVRAM
Works with
CPU-700-D3
CPU-700-D3R
Operation and Diagnostic
LEDs
Power Supply
Functioning
Hold
Safe
Communication
Fail
Internal Power Supply
Current Consumption
5Vdc
200 mA

 

Power Supply Module (Redundancy Capacity):

Model
PS-AC-R (for AC input voltage)
PS-DC-R (for DC input voltage)
Operation Mode
Main or Backup
Operating Voltages
90 to 264 Vdc PS-AC-R
20 to 30 Vdc PS-DC-R
Outputs (all isolated)
5,2 Vdc +/- 2% @ 3A
24 Vdc +/- 10% @ 300 mA
Diagnostic LEDs
5 Vdc Indicator
24 Vdc Indicator
Failure Indicator
Relay for Failure
Announcement
Normally Closed

 

Redundant Processor Module (CPU):

Model
CPU-700-D3R
Redundancy Type
Hot Standby
Configuration
Main or Backup CPU
Specific Features
Controller Switchover in 40 ms
Automatic Configuration and Parameters Bypass
Self Configurable Based on Controlling CPU
Number of Ports
4 Independent Ports
P1 - Modbus RTU (RS-232C)
P2 - Modbus RTU (RS-485)
P3 - E/S Remote (RS-485)
ICP - Inter-CPU-Port for data Updating
Port Connections
P1 - DB9 Female
P2 e P3 Terminals
ICP Connection for Redundancy
Remote I/O Port Type
Master
Baud Rates:
P1 - 1200bps to 57.6Kbps
P2 - 1200bps to 115.5Kbps
P3 - 57.6Kbps to 230.4Kbps
Isolation on RS-485
1600Vms @ 1 minute
2000Vms @ 1 second
Configuration Memory
NVRAM
Remote I/O Works with
RIO-700-D3
Operation and Diagnostic
LEDs
Power Supply
Functioning
Hold
Safe
Communication
Fail
Internal Power Supply Current Consumption 5Vdc
240 mA

* The P3 Remote I/O Port works with the R-700-D3 module.

 

Serial Interface:

Model
SI-700
Communications Channel
1
Data Communication Interface
RS232 / RS485
Baud Rates
Up to 200 Kbps
RS232
Half duplex mode or full duplex
Isolation
1600 Vms @ 1 minute
Internal Power Supply Current Consumption 5Vdc
100 mA

 

Optical Interface:

Model
OPT-700
Communications Channel
1
Data Communication Interface
62,5 or 50/125?m optical cable with ST connections
Baud Rates
4000 m
RS232
Half duplex mode or full duplex
Isolation
1600 Vms @ 1 minute
Current Consumption
Internal IMB power supply 12-30Vdc 200mA

 

Scanner DeviceNet*:

Model
DN-700
Number of Channels
1
Maximum number of Nodes
64
Baud Rates
125, 250 and 500 Kbps
Isolation
Optical 500V
Field Connector
Standard Phoenix 5-pin Terminal
Configuration Memory
Flash
Operation LEDs
Run Ready
Network
Module
PC Port
RS-232C / DB-9 Male (Firmware updates)
Internal Power Supply Current Consumption 5Vdc
310 mA

 

Scanner Profibus-DP*

Model
DP-700
Number of Channels
1
Maximum number of Nodes
125
Baud Rates
9.6 K up to 12 Mpbs
Isolation
500V Optical
Field Connector
DB-9 Female
Configuration Memory
Flash
Operation LEDs
Run
Ready State
Error
PC Port
RS-232C / DB-9 Male (Firmware Updates)
Internal Power Supply Current Consumption 5Vdc
610 mA

* Under request

 

Modbus/TCP Ethernet Module

Model
ENET-700
Open TCP Connections
Maximum of 8
Communication Channels
10 Base-T (RJ45)
RS-232C (DB-9 Female)
RS-485 (Terminals)
Serial Baud Rates
300 bps to 38.4 Kbps
RS-485 Isolation
1600Vrms @ 1 minute
2000Vrms @ 1 second
Compatibility
Ethernet Version 2.0/IEEE 802.3
Management
Telnet Login and SNMP (read only)
Diagnostic LEDs
L1-Good Link
L2-Error Code
L3-Error Code
L4-Error Code
Firmware
New Software can be downloaded via TFTP or serial port
Internal Power Supply Current Consumption 5Vdc
270 mA

 

Modbus RTU and TCP/IP Processor

Model
MB700
Open Connection
Maximum 40
Communication Ports
Ethernet 1 Port ethernet @ 10 Mbits 10 Base-T (RJ-45 Connector)
Serial 1 Port EIA 232 @ 9,6 Kbps-115,2 Kbps (RJ11 Connector)
  1 Port EIA 485 @ 9,6 Kbps-115,2 Kbps
H1 1 Port for redundance
EIA485 Isolation
1600 Vms @ 1 minute
2000 Vms @ 1 second
Compatability
Ethernet version 2.0 / IEEE 802,3
Status Indication
Ethernet Version 2.0/IEEE 802.3
Firmware
Telnet Login and SNMP (read only)
Diagnostic LEDs
+5 Vdc: Green LED indicating module energizing
Run: Green LED indicating program running
Hold: Yellow LED indicating program is hold
Fail: Red LED indicating processor failure
232/485TX: Green LED indicating transmission of EIA 232 and EIA 485 data
ETH 10: Green LED indicating Ethernet cable connected
FF H1: Green LED indicating transmission of Fieldbus H1 data
Standby: Green LED indicating Standby mode (waiting mode when the MB700 is redundant)
Force: Not used
Firmware
New Software can be update through serial port or ethernet
Internal Power Supply Current Consumption 5Vdc
950 mA

 

Basic Components

Name Description Part Number
CPU Module
CPU module with 128 Kbytes of non-volatile memory and a microcontroller of 15 MHz with real time clock and remote I/O (Master)*

CPU module with 128 Kbytes of non-volatile memory and a microcontroller of 15 MHz with real time clock and remote I/O (Redundant Module)*
CPU-700-D3


CPU-700-D3R
Power Supply Module
Power Supply for IMB: Input: 90 to 264 Vac output: 5 Vdc @ 3 A and 24 Vdc @ 300mA with redundancy capability (isolation between them)

Power Supply for IMB: Input: 20 to 30 Vdc output: 5 Vdc @ 3 A and 24 Vdc @ 300mA with redundancy capability (isolation between them)
PS-AC-R


PS-DC-R
Rack
Rack with 4 slots
R-700-4
Terminator
Terminator for the last rack
T-700
Flat Cable
Flat cable to connect 2 racks - length 6,5 cm
Flat cable to connect 2 racks - length 65,0 cm
Flat cable to connect 2 racks - length 81,5 cm
Flat cable to connect 2 racks - length 98,0 cm
Flat cable to connect 2 racks - length 114,0 cm
FC-700-0
FC-700-1
FC-700-2
FC-700-3
FC-700-4
Flat Cable Connection Kit
Flat cable connection kit
FCC-CONN
Configurator of the LC700
Software for Hardware settings, programming and optimization (Windows 95, Windows NT, Windows 98, Windows 2000, Windows XP)
CONF700
Blind Module
Blind module to fill empty slots
M-000
Inter-CPU Cable
Cable used for connection of redundant CPUs
ICP-700-D3
OPC-Server
OPC-Server for the LC700 system
OPC-700
(extension kit)
Extension for DB9 connector
DB9-EXT
Cable for Local Configuration (RS-232)
Cable EIA-232 computer -LC700 (183 cm)
C232-700
Serial Cable
EIA RS-232 Cable to connect CPU-700-D3 and ENET-700
C232-1-700
Serial Cable
EIA 232 Cable to connect redundant CPU-700-D3R and ENET-700
C232-2-700

* Memory available for configuration CPU-700-D3:28 Kbytes, CPU-700-D3R:24 Kbytes

 

Modules I/O

Name Description Part Number
DC Input
2 groups of 8 24 Vdc inputs (optically isolated)
2 groups of 8 48 Vdc inputs (optically isolated)
2 groups of 8 60 Vdc inputs (optically Isolated)
2 groups of 8 125 Vdc inputs (optically isolated)
2 groups of 8 24 Vdc inputs (optically isolated) (sink)
M-001
M-002
M-003
M-004
M-005
AC Input
2 groups of 4 120 Vac inputs (optically isolated)
2 groups of 4 240 Vac inputs (optically isolated)
2 groups of 8 120 Vac inputs (optically isolated)
2 groups of 8 240 Vac inputs (optically isolated)
M-010
M-011
M-012
M-013
On/Off Switches
1 group of 8 push-button On/Off inputs (optically isolated)
M-020
Transistor Output
1 group of 16 Open Collector Outputs (optically isolated)
2 groups of 8 Transistor Outputs Source (optically isolated)
M-101
M-102
Triac Output
1 group of 8 120/240 Vac Outputs (optically isolated)
2 groups of 8 120/240 Vac Outputs (optically isolated)
M-110
M-111
Relay Output
2 groups of 4 N.O. Relay Outputs with internal RC (optically isolated)
2 groups of 4 N.C. Relay Outputs with internal RC (optically isolated)
1 group of 4 N.O. and 1 Group of 4 N.C. Relay Outputs with internal RC (optically isolated)
2 groups of 8 N.O. Relays Outputs (optically isolated)
2 groups of 4 N.O. Relay Outputs (optically isolated)
2 groups of 4 N.O. Relay Outputs (optically isolated)
1 group of 4 N.O. and 1 Group of 4 N.C. Relay Outputs (optically isolated)
2 groups of 8 N.O. Relay Outputs with internal RC (optically isolated)
M-120
M-121
M-122
M-123
M-124
M-125
M-126
M-127
DC Input / Relay Output
1 group of 8 24 Vdc Inputs and 1 Group of 4 N.O. Relay Outputs (optically isolated)
1 group of 8 48 Vdc Inputs and 1 Group of 4 N.O. Relay Outputs (optically isolated)
1 group of 8 60 Vdc Inputs and 1 Group of 4 N.O. Relay Outputs (optically isolated)
1 group of 8 24 Vdc Inputs and 1 Group of 4 N.C. Relay Outputs (optically isolated)
1 group of 8 48 Vdc Inputs and 1 Group of 4 N.C. Relay Outputs (optically isolated)
1 group of 8 60 Vdc Inputs and 1 Group of 4 N.C. Relay Outputs (optically isolated)
1 group of 8 24 Vdc Inputs and 1 Group with 2 N.O. and 2 N.C. Relay Outputs (optically isolated)
1 group of 8 48 Vdc Inputs and 1 Group with 2 N.O. and 2 N.C. Relay Outputs (optically isolated)
1 group of 8 60 Vdc Inputs and 1 Group with 2 N.O. and 2 N.C. Relay Outputs (optically isolated)
M-201
M-202
M-203
M-204
M-205
M-206
M-207
M-208
M-209
Analog Input
8 Voltage/Current Analog Inputs with internal Shunt Resistor (optically isolated)
8 Voltage/Current Analog Inputs with internal Shunt Resistor (optically isolated)
8 Low Level Signal (TC, RTD, mV, .) Inputs (optically isolated)
M-401-R
M-401-DR
M-402
Analog Output
4 Current and Voltage Analog Outputs (optically isolated)
M-501
Pulse Input
2 groups of 8 pulse inputs 0-100 Hz-24Vdc (optically isolated)
2 groups of 8 pulse inputs 0-10 KHz- 24 Vdc (optically isolated)
2 groups of 8 pulse inputs 0-10 KHz- AC (optically isolated)
2 groups of 8 pulse inputs 0-10 KHz- 24 Vdc (optically isolated)
M-302
M-303
M-304
M-305
Fieldbus Module
One H1 Fieldbus Foundation Channel (Isolated)
FB-700
Ethernet Module
Modbus/TCP 10Base-T Ethernet Module
ENET-700
Profibus Module**
Profibus-DP and Profibus-PA high performance master
DP-700
DeviceNet Module**
High performance Device Net master
DN-700
Modbus Module
Modbus RTU and TCP/IP Processor
MB-700
Optical Interface Module
EIA 232/485 for Fiber Optical Converter
OPT-700
Serial Interface Module
EIA 232 / EIA RS485 Interface
SI-700
Rio interface Module
I/O Interface module with 6 kbytes of EEPROM for configuration and a microcontroller of 15 MHz and remote I/O (Slave)
RIO-700-D3

** Check for availability in the factory


To request more information, please fill the form below.
First Name:
Last Name:
Title:
Company:
Address:
City:
E-mail:
Phone: -
Comments: